$50 = Border-Free Shipping

ESCT RC75 1000A Rogowski Coil Current Sensor - 75mm Diameter, 85mV/kA Output, 1000 Amp Capacity with 3 Meter Cable - Ideal for Power Monitoring, Energy Management & Industrial Electrical Measurements
$81.95
$149
Safe 45%
ESCT RC75 1000A Rogowski Coil Current Sensor - 75mm Diameter, 85mV/kA Output, 1000 Amp Capacity with 3 Meter Cable - Ideal for Power Monitoring, Energy Management & Industrial Electrical Measurements
ESCT RC75 1000A Rogowski Coil Current Sensor - 75mm Diameter, 85mV/kA Output, 1000 Amp Capacity with 3 Meter Cable - Ideal for Power Monitoring, Energy Management & Industrial Electrical Measurements
ESCT RC75 1000A Rogowski Coil Current Sensor - 75mm Diameter, 85mV/kA Output, 1000 Amp Capacity with 3 Meter Cable - Ideal for Power Monitoring, Energy Management & Industrial Electrical Measurements
$81.95
$149
45% Off
Quantity:
Delivery & Return: Free shipping on all orders over $50
Estimated Delivery: 10-15 days international
28 people viewing this product right now!
SKU: 35339403
Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay
shop
Description

ESCT-RC75-1000A, Rogowski Coil, 75mm Diameter, 85mV/kA 1000 Amp Recommended, 3 Meter Cable length

Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). 

    • Rated insulation voltage 1000 V Cat III PD2
    • Accuracy Class 0.5 (IEC 61869-2)
    • Protection degree IP67
    • 3 m output cable (other lengths available see page 8)
    • Ambient temperature 40 °C … +80 °C
    • Very flexible and thin coil: 6.1 mm
    • Slot for attaching the loop on the primary with a cable tie
    • An innovative patented clasp drastically reduces the positioning error near the closing
    • Internal shield for enhanced measurement accuracy at low primary currents.

    Advantages

    • Thin, flexible, and light weight solution
    • Very low positioning error
    • Quick, non-intrusive and easy setup
    • A single sensor for a large current range without overload
    • Less influenced by external fields
    • Adaptable for a large range of cable diameters

    Applications

    • MV/LV substations on LV side: Transformer Condition Monitoring
    • Power metering: current measurement for active power calculation
    • Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
    • Power quality monitoring: electrical loads and distribution system equipment
    • Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
    • Remote Terminal Units (RTU)
    • Phasor Measurement Units (PMU)

    Standards

    • IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012
    • 1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012
    • 1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016
    • UL
      Specification
      LEM Part NumberESCT-RC75-1000A
      FunctionAC Current Measurement
      Measuring Range0 - 5,000 Amp RMS ( for wider range)
      Secondary Voltage (Sensitivity)85mV
      Frequency Measuring Range50-300kHz
      Operating VoltageSelf Powered
      Accuracy0.5% from 25 to 5000 Amp
      Phase Angle< 0.004
      Coil Diameter (?)7cm
      Coil Circumference22cm
      Integrator to Coil Cable 3M Twisted Pair
      Maximum Voltage1000V Reinforced insulation according to EN 61010-1
      Operating Temperature-15°C to 65°C
      Storage Temperature-45°C to 80°C
      Isolation (50Hz, 1 min)7.4kV
      Overload300,000 Amp
      Termination Style2 Stripped Wires
      Weight130g
      Factory Pack Qty1
      Certifications

       

      UL, ROHS
      Datasheet
      Application Notes

      1) The Rogowski coil can measure any primary current as there is no saturation effect.

      2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)

      3) Frequency bandwidth and phase shift modeling schematic can be provided on request.

      4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)

      5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil.

      6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

       

      More
      Shipping & Returns

      For all orders exceeding a value of 100USD shipping is offered for free.

      Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.

      Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.


      You Might Also Like